| To
acquire a complete data acquisitions of voltage and current at the
propose location. |
|
Reports
will be provided which comprise as follows: |
|
|
|
Detail Technical Analysis report : |
|
- |
Investigation procedures:
Visual inspection on the existing electrical wiring
installation system to determine the conditions and
adequacies of the wiring and grounding system and to acquire
a complete data acquisition of voltage and current events at
the propose sites. |
|
- |
The findings:
To identify causes of power quality problems and describe
the effects of each. |
|
- |
Conclusions of
findings. |
|
- |
Recommendations
of mitigation procedure. |
|
 |
|
| |
|
Power
Analysis Summary report : |
|
 |
|
- |
The initial
conditions section. This section defines the power
conditions at the above location. Events are defined as
changes in the monitored voltages. These changes may be
subtle or severe. The power tolerance curve provides a
graphical representation of the likelihood of an event to
disrupt equipment operations. |
|
- |
The Events
section. This is a summary of the voltage events that
occurred at this location during the monitor interval. .
Events are defined as changes in the monitored voltage.
These changes may be subtle or severe. The power tolerance
curve provides a graphical representation of the likelihood
of an event to disrupt equipment operations. |
|
- |
The Voltage Current and Frequency, (VIF),
section. This section contains summaries for each of these
parameters during the monitoring interval. |
|
- |
The Harmonics section. This contains the
voltage and current harmonic distortion summaries acquired
during the monitoring interval. |
|
- |
The Power section. This contains the VA,
VARS., Watts, and Power factor acquired during the
monitoring interval. For multiphase locations, voltage and
current imbalances are also included. |
|
|
| |
|
Capability Reliability Report |
|
- |
The
report will consists of the Capability and the Reliability of the
power system. Calculation and Distribution of the Load, Capacity of
the Transformer and Circuit, Future Upgrade and Usage. |
| |
|
Power
Quality Audit Report |
|
- |
The
report will consists of the Simplified Schematic Diagram, Waveform
graph, Finding, Conclusion, Recommendation and Analysis Compliance
to Harmonised EN50160 Standard. |
| |
|
Infrared
thermo graphic surveys report (optional) : |
|
- |
A detailed report including both thermal
and photographic images are created. The report will detail
the absolute temperature measurement of the hot spots and
loose connections in the electrical installation
distribution system of the building. |
|
- |
An infrared scanner can detect
overheating of electrical switchgear, transformers, circuit
breakers and electrical connections. A digital display
indicates the temperature rise above ambient. |
|
 |
|