To acquire a complete data acquisitions of voltage and current at the propose location.
Reports will be provided which comprise as follows:
 
Detail Technical Analysis report :

-

Investigation procedures:
Visual inspection on the existing electrical wiring installation system to determine the conditions and adequacies of the wiring and grounding system and to acquire a complete data acquisition of voltage and current events at the propose sites.

-

The findings:
To identify causes of power quality problems and describe the effects of each.

-

Conclusions of findings.

-

Recommendations of mitigation procedure.

 
Power Analysis Summary report :

-

The initial conditions section. This section defines the power conditions at the above location. Events are defined as changes in the monitored voltages. These changes may be subtle or severe. The power tolerance curve provides a graphical representation of the likelihood of an event to disrupt equipment operations.

-

The Events section. This is a summary of the voltage events that occurred at this location during the monitor interval. . Events are defined as changes in the monitored voltage. These changes may be subtle or severe. The power tolerance curve provides a graphical representation of the likelihood of an event to disrupt equipment operations.

-

The Voltage Current and Frequency, (VIF), section. This section contains summaries for each of these parameters during the monitoring interval.

-

The Harmonics section. This contains the voltage and current harmonic distortion summaries acquired during the monitoring interval.

-

The Power section. This contains the VA, VARS., Watts, and Power factor acquired during the monitoring interval. For multiphase locations, voltage and current imbalances are also included.
 
Capability Reliability Report

-

The report will consists of the Capability and the Reliability of the power system. Calculation and Distribution of the Load, Capacity of the Transformer and Circuit, Future Upgrade and Usage.
 
Power Quality Audit Report

-

The report will consists of the Simplified Schematic Diagram, Waveform graph, Finding, Conclusion, Recommendation and Analysis Compliance to Harmonised EN50160 Standard.
 
Infrared thermo graphic surveys report (optional) :

-

A detailed report including both thermal and photographic images are created. The report will detail the absolute temperature measurement of the hot spots and loose connections in the electrical installation distribution system of the building.

-

An infrared scanner can detect overheating of electrical switchgear, transformers, circuit breakers and electrical connections. A digital display indicates the temperature rise above ambient.